docs/source/control/control_system.rst

Lines changed: 14 additions & 16 deletions
Original file line numberDiff line numberDiff line change
@@ -4,34 +4,34 @@ Common
44
Data Flow
55
---------
66

7-
The two figures below show the structure and data flow in a typical simulation model as well as an example of the internal structure of a discrete-time control system. The text in italics refers to the default object names used in the software. In discrete-time control systems, the signals are collected into the following :class:`types.SimpleNamespace` objects:
7+
The two figures below show the structure and data flow in a typical simulation model as well as an example of the internal structure of a discrete-time control system. The text in italics refers to the default object names used in the software. In discrete-time control systems, the signals are collected into the following :class:`types.SimpleNamespace` objects:
88

9-
- The object `fbk` contains feedback signals for the controllers. These signals can be measured quantities (such as the measured DC-bus voltage `fbk.u_dc`) as well as estimated quantities (such as the estimated stator flux linkage `fbk.psi_s`).
9+
- The object `fbk` contains feedback signals for the controllers. These signals can be measured quantities (such as the measured DC-bus voltage `fbk.u_dc`) as well as estimated quantities (such as the estimated stator flux linkage `fbk.psi_s`).
1010

11-
- The object `ref` contains the reference signals, both externally provided (such as `ref.w_m` for the angular speed reference) and internally generated (such as `ref.d_c_abc` for the duty ratios).
11+
- The object `ref` contains the reference signals, both externally provided (such as `ref.w_m` for the angular speed reference) and internally generated (such as `ref.d_c_abc` for the duty ratios).
1212

1313
These objects `fbk` and `ref` may propagate through several blocks (implemented as classes in the software), which may add new signals or modify the existing one. At the end of their propagation chain, both objects `fbk` and `ref` are saved to the lists. Therefore, the most relevant internal signals of the control system are directly accessible after the simulation. Furthermore, the states and inputs of the continuous-time system model are also saved. In the post-processing stage, the saved data is converted to the NumPy arrays.
1414

1515
.. figure:: figs/overall_system.svg
1616
:width: 100%
1717
:align: center
1818
:alt: Block diagram of the control system.
19-
20-
Block diagram illustrating the structure and data flow in a typical simulation model. The lower part of the figure illustrates how the data is saved. The post-processing is done after the simulation. The internal structure of a typical control system is exemplified in the figure below.
19+
20+
Block diagram illustrating the structure and data flow in a typical simulation model. The lower part of the figure illustrates how the data is saved. The post-processing is done after the simulation. The internal structure of a typical control system is exemplified in the figure below.
2121

2222
.. figure:: figs/discrete_control_system.svg
2323
:width: 100%
2424
:align: center
2525
:alt: Block diagram of the control system.
26-
27-
Block diagram exemplifying the internal structure of a typical cascade control system. The object `ref` at the control system output should contain the sampling period `T_s` and the converter duty ratios `d_c_abc` for the carrier comparison. The observer does not necessarily exist in all control systems (or it can be replaced with, e.g., a phase-locked loop).
26+
27+
Block diagram exemplifying the internal structure of a typical cascade control system. The object `ref` at the control system output should contain the sampling period `T_s` and the converter duty ratios `d_c_abc` for the carrier comparison. The observer does not necessarily exist in all control systems (or it can be replaced with, e.g., a phase-locked loop).
2828

2929
Main Control Loop
3030
-----------------
3131

3232
A template for the main control loop is available in the base class for discrete-time control systems in :class:`motulator.common.control.ControlSystem`. The main control loop in this template has the following steps:
3333

34-
1. Get the feedback signals `fbk` for the controllers from the outputs of the continuous-time system model `mdl`. This step may contain first getting the measurements and then optionally computing the observer outputs (or otherwise manipulating the measured signals).
34+
1. Get the feedback signals `fbk` for the controllers from the outputs of the continuous-time system model `mdl`. This step may contain first getting the measurements and then optionally computing the observer outputs (or otherwise manipulating the measured signals).
3535
2. Get the reference signals `ref` and compute the controller outputs based on the feedback signals `fbk`. Cascade control systems may contain multiple controllers, where the output of the outer controller is the reference signal for the inner controller.
3636
3. Update the states of the control system for the next sampling instant.
3737
4. Save the feedback signals `fbk` and the reference signals `ref` so they can be accessed after the simulation.
@@ -54,14 +54,14 @@ The figure below shows a 2DOF PI controller with an optional feedforward term. I
5454
u &= k_\mathrm{t}r - k_\mathrm{p}y + u_\mathrm{i} + u_\mathrm{ff}
5555
:label: 2dof_pi
5656
57-
where :math:`r` is the reference signal, :math:`y` is the measured (or estimated) feedback signal, :math:`u_\mathrm{i}` is the the integral state, and :math:`u_\mathrm{ff}` is the optional feedforward signal. Furthermore, :math:`k_\mathrm{t}` is the reference-feedforward gain, :math:`k_\mathrm{p}` is the proportional gain, and :math:`k_\mathrm{i}` is the integral gain. Setting :math:`k_\mathrm{t} = k_\mathrm{p}` and :math:`u_\mathrm{ff} = 0` results in the standard PI controller. This 2DOF PI controller can also be understood as a state-feedback controller with integral action and reference feedforward [#Fra1997]_.
57+
where :math:`r` is the reference signal, :math:`y` is the measured (or estimated) feedback signal, :math:`u_\mathrm{i}` is the the integral state, and :math:`u_\mathrm{ff}` is the optional feedforward signal. Furthermore, :math:`k_\mathrm{t}` is the reference-feedforward gain, :math:`k_\mathrm{p}` is the proportional gain, and :math:`k_\mathrm{i}` is the integral gain. Setting :math:`k_\mathrm{t} = k_\mathrm{p}` and :math:`u_\mathrm{ff} = 0` results in the standard PI controller. This 2DOF PI controller can also be understood as a state-feedback controller with integral action and reference feedforward [#Fra1997]_.
5858

5959
.. figure:: figs/2dof_pi.svg
6060
:width: 100%
6161
:align: center
6262
:alt: 2DOF PI controller.
6363

64-
2DOF PI controller with an optional feedforward term. The operator :math:`1/s` refers to integration. A discrete-time variant of this controller with the integrator anti-windup is implemented in the :class:`motulator.common.control.PIController` class.
64+
2DOF PI controller with an optional feedforward term. The operator :math:`1/s` refers to integration. A discrete-time variant of this controller with the integrator anti-windup is implemented in the :class:`motulator.common.control.PIController` class.
6565

6666
Disturbance-Observer Structure
6767
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
@@ -71,7 +71,7 @@ The controller :eq:`2dof_pi` can be equally represented using the disturbance-ob
7171
.. math::
7272
\frac{\mathrm{d} u_\mathrm{i}}{\mathrm{d} t} &= \alpha_\mathrm{i}\left(u - \hat v\right) \\
7373
\hat v &= u_\mathrm{i} - (k_\mathrm{p} - k_\mathrm{t})y + u_\mathrm{ff} \\
74-
u &= k_\mathrm{t}\left(r - y\right) + \hat v
74+
u &= k_\mathrm{t}\left(r - y\right) + \hat v
7575
:label: 2dof_pi_disturbance_observer
7676
7777
where :math:`\alpha_\mathrm{i} = k_\mathrm{i}/k_\mathrm{t}` is the redefined integral gain and :math:`\hat v` is the input-equivalent disturbance estimate. This structure is convenient to prevent the integral windup that originates from the actuator saturation [#Fra1997]_. The actuator output is limited in practice due to physical constraints. Consequently, the realized actuator output is
@@ -85,7 +85,7 @@ where :math:`\mathrm{sat}(\cdot)` is the saturation function. If this saturation
8585
\frac{\mathrm{d} u_\mathrm{i}}{\mathrm{d} t} = \alpha_\mathrm{i}\left(\bar{u} - \hat v \right)
8686
:label: anti_windup
8787
88-
The other parts of the above controller are not affected by the saturation.
88+
The other parts of the above controller are not affected by the saturation.
8989

9090
Discrete-Time Algorithm
9191
^^^^^^^^^^^^^^^^^^^^^^^
@@ -99,7 +99,7 @@ The discrete-time variant of the controller :eq:`2dof_pi_disturbance_observer` w
9999
\bar{u}(k) &= \mathrm{sat}[u(k)]
100100
:label: discrete_2dof_pi
101101
102-
where :math:`T_\mathrm{s}` is the sampling period and :math:`k` is the discrete-time index. This algorithm corresponds to the actual implementation in the :class:`motulator.common.control.PIController` class.
102+
where :math:`T_\mathrm{s}` is the sampling period and :math:`k` is the discrete-time index. This algorithm corresponds to the actual implementation in the :class:`motulator.common.control.PIController` class.
103103

104104
.. _complex-vector-2dof-pi-controller:
105105

@@ -113,7 +113,7 @@ As shown in the figure below, the 2DOF PI controller presented above can be exte
113113
\boldsymbol{u} &= \boldsymbol{k}_\mathrm{t}\boldsymbol{r} - \boldsymbol{k}_\mathrm{p}\boldsymbol{y} + \boldsymbol{u}_\mathrm{i} + \boldsymbol{u}_\mathrm{ff}
114114
:label: complex_vector_2dof_pi
115115
116-
where :math:`\boldsymbol{u}` is the output of the controller, :math:`\boldsymbol{r}` is the reference signal, :math:`\boldsymbol{u}_\mathrm{i}` is the the integral state, and :math:`\boldsymbol{u}_\mathrm{ff}` is the optional feedforward signal. Furthermore, :math:`\boldsymbol{k}_\mathrm{t}` is the reference-feedforward gain, :math:`\boldsymbol{k}_\mathrm{p}` is the proportional gain, and :math:`\boldsymbol{k}_\mathrm{i}` is the integral gain.
116+
where :math:`\boldsymbol{u}` is the output of the controller, :math:`\boldsymbol{r}` is the reference signal, :math:`\boldsymbol{u}_\mathrm{i}` is the the integral state, and :math:`\boldsymbol{u}_\mathrm{ff}` is the optional feedforward signal. Furthermore, :math:`\boldsymbol{k}_\mathrm{t}` is the reference-feedforward gain, :math:`\boldsymbol{k}_\mathrm{p}` is the proportional gain, and :math:`\boldsymbol{k}_\mathrm{i}` is the integral gain.
117117

118118
.. figure:: figs/complex_vector_2dof_pi.svg
119119
:width: 100%
@@ -131,5 +131,3 @@ The discrete-time implementation of :eq:`complex_vector_2dof_pi` with the anti-w