From f65d805e8304768ab599e70055b78b4535e546bb Mon Sep 17 00:00:00 2001 From: danielfeismann Date: Thu, 7 Aug 2025 08:41:37 +0200 Subject: [PATCH 1/4] Provide standard asset parameter for 3wTransformer --- CHANGELOG.md | 3 +- .../models/input/grid/transformer3w.md | 58 +++++++++++++++++++ 2 files changed, 60 insertions(+), 1 deletion(-) diff --git a/CHANGELOG.md b/CHANGELOG.md index 6bf312404..b18c2a07c 100644 --- a/CHANGELOG.md +++ b/CHANGELOG.md @@ -7,7 +7,8 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0 ## [Unreleased/Snapshot] ### Added --Added weathersource documentation [#1390](https://github.com/ie3-institute/PowerSystemDataModel/issues/1390) +- Added weathersource documentation [#1390](https://github.com/ie3-institute/PowerSystemDataModel/issues/1390) +- Added standard asset parameter for `3wTransformer` in `ReadTheDocs` [#1417](https://github.com/ie3-institute/PowerSystemDataModel/issues/1417) ### Fixed - Fixed small issues in tests [#1400](https://github.com/ie3-institute/PowerSystemDataModel/issues/1400) diff --git a/docs/readthedocs/models/input/grid/transformer3w.md b/docs/readthedocs/models/input/grid/transformer3w.md index 652706df5..1dd81f5a2 100644 --- a/docs/readthedocs/models/input/grid/transformer3w.md +++ b/docs/readthedocs/models/input/grid/transformer3w.md @@ -178,9 +178,67 @@ All impedances and admittances are given with respect to the higher voltage side ``` +## Standard Three Winding Transformer Types + + +Following there are some standard three winding transformer types with their source. + +```{list-table} + :widths: auto + :class: wrapping + :header-rows: 1 + + * - uuid + - bM + - dPhi + - dV + - gM + - id + - rScA + - rScB + - rScC + - sRatedA + - sRatedB + - sRatedC + - tapMax + - tapMin + - tapNeutr + - vRatedA + - vRatedB + - vRatedC + - xScA + - xScB + - xScC + - source + + * - 5a890aae-b9c9-4ebf-8a49-8850ae9df402 + - -519.48 + - 0.0 + - 1.5 + - 12.98 + - HöS_HS_MS + - 0.15 + - 0.58 + - 1.15 + - 120000.0 + - 60000.0 + - 40000.0 + - 10 + - -10 + - 0 + - 380.0 + - 110.0 + - 20.0 + - 24.02 + - 60.15 + - 200.75 + - Dissertation C. Kittl TU Dortmund[^cite_kittl2022] +``` + ## Caveats Nothing - at least not known. If you found something, please contact us! [^cite_gremmel1999]: Gremmel, H., Ed., Schaltanlagen. Cornelsen Verlag, 1999, Vol. 10, isbn: 3-464-48235-9. +[^cite_kittl2022]: Kittl, C., Entwurf und Validierung eines individualitätszentrierten, interdisziplinären Energiesystemsimulators basierend auf ereignisdiskreter Simulation und Agententheorie, Dortmunder Beiträge zu Energiesystemen, Energieeffizienz und Energiewirtschaft, Shaker Verlag, 2022, Vol. 25, isbn: 9-783-84408463-4. From 82c20cb455c335915ba373f4ffa994e717831b18 Mon Sep 17 00:00:00 2001 From: danielfeismann Date: Thu, 7 Aug 2025 08:49:47 +0200 Subject: [PATCH 2/4] correct values --- .../models/input/grid/transformer3w.md | 24 +++++++++---------- 1 file changed, 12 insertions(+), 12 deletions(-) diff --git a/docs/readthedocs/models/input/grid/transformer3w.md b/docs/readthedocs/models/input/grid/transformer3w.md index 1dd81f5a2..672b6cc33 100644 --- a/docs/readthedocs/models/input/grid/transformer3w.md +++ b/docs/readthedocs/models/input/grid/transformer3w.md @@ -212,26 +212,26 @@ Following there are some standard three winding transformer types with their sou - source * - 5a890aae-b9c9-4ebf-8a49-8850ae9df402 - - -519.48 + - -519.4864 - 0.0 - 1.5 - - 12.98 + - 12.985 - HöS_HS_MS - - 0.15 - - 0.58 - - 1.15 - - 120000.0 - - 60000.0 - - 40000.0 + - 0.1444 + - 0.5776 + - 1.1552 + - 300000.0 + - 300000.0 + - 100000.0 - 10 - -10 - 0 - 380.0 - 110.0 - - 20.0 - - 24.02 - - 60.15 - - 200.75 + - 30.0 + - 24.066121 + - 60.164118 + - 199.750106 - Dissertation C. Kittl TU Dortmund[^cite_kittl2022] ``` From 5ac249db9ff5e69af4ec0ca7131faf90af6376cb Mon Sep 17 00:00:00 2001 From: danielfeismann Date: Thu, 7 Aug 2025 10:47:42 +0200 Subject: [PATCH 3/4] providing example file for 3wTransformer --- input/StandardAssetTypes/transformer_3_w_type_input.csv | 2 ++ 1 file changed, 2 insertions(+) create mode 100644 input/StandardAssetTypes/transformer_3_w_type_input.csv diff --git a/input/StandardAssetTypes/transformer_3_w_type_input.csv b/input/StandardAssetTypes/transformer_3_w_type_input.csv new file mode 100644 index 000000000..57b3194ca --- /dev/null +++ b/input/StandardAssetTypes/transformer_3_w_type_input.csv @@ -0,0 +1,2 @@ +uuid,b_m,d_phi,d_v,g_m,id,r_sc_a,r_sc_b,r_sc_c,s_rated_a,s_rated_b,s_rated_c,tap_max,tap_min,tap_neutr,v_rated_a,v_rated_b,v_rated_c,x_sc_a,x_sc_b,x_sc_c +62aef8ec-7e68-43e5-9678-8cde101f0116,-519.4864,0.0,1.5,12.985,HoeS_HS_MS,0.1444,0.5776,1.1552,300000.0,300000.0,100000.0,10,-10,0,380.0,110.0,30.0,24.066121,60.164118,199.750106 From fe6cb799187e182c363aa47d14df61988241f4f3 Mon Sep 17 00:00:00 2001 From: danielfeismann Date: Thu, 7 Aug 2025 10:47:49 +0200 Subject: [PATCH 4/4] minor adaptions --- docs/readthedocs/models/input/grid/transformer2w.md | 7 +++---- docs/readthedocs/models/input/grid/transformer3w.md | 8 ++++---- 2 files changed, 7 insertions(+), 8 deletions(-) diff --git a/docs/readthedocs/models/input/grid/transformer2w.md b/docs/readthedocs/models/input/grid/transformer2w.md index 056969933..a0fd0f8fb 100644 --- a/docs/readthedocs/models/input/grid/transformer2w.md +++ b/docs/readthedocs/models/input/grid/transformer2w.md @@ -137,10 +137,9 @@ A list with some standard transformer types can be found here: [Standard Two Win ## Standard Two Winding Transformer Types -Following there are some standard two winding transformer types with their source. A ``csv file`` containing the types listed -below can be found [here](https://github.com/ie3-institute/PowerSystemDataModel/tree/dev/input/StandardAssetTypes). This -file can be used directly for any simulation with ``simona``. -The transformers which source is ``simBench`` are from [here](https://simbench.de/en/download/datasets/). +Following there are some standard two winding transformer types with their source. The types are listed below in a ``csv file`` [here](https://github.com/ie3-institute/PowerSystemDataModel/tree/dev/input/StandardAssetTypes). This +file can be used directly for any simulation with [SIMONA](https://github.com/ie3-institute/simona). +The source for transformers from ``simBench`` can be found [here](https://simbench.de/en/download/datasets/). ```{list-table} :widths: auto diff --git a/docs/readthedocs/models/input/grid/transformer3w.md b/docs/readthedocs/models/input/grid/transformer3w.md index 672b6cc33..35ec84d33 100644 --- a/docs/readthedocs/models/input/grid/transformer3w.md +++ b/docs/readthedocs/models/input/grid/transformer3w.md @@ -180,8 +180,8 @@ All impedances and admittances are given with respect to the higher voltage side ## Standard Three Winding Transformer Types - -Following there are some standard three winding transformer types with their source. +Following there are some standard three winding transformer types with their source. The types are listed below in a ``csv file`` [here](https://github.com/ie3-institute/PowerSystemDataModel/tree/dev/input/StandardAssetTypes). This +file can be used directly for any simulation with [SIMONA](https://github.com/ie3-institute/simona). ```{list-table} :widths: auto @@ -211,12 +211,12 @@ Following there are some standard three winding transformer types with their sou - xScC - source - * - 5a890aae-b9c9-4ebf-8a49-8850ae9df402 + * - 62aef8ec-7e68-43e5-9678-8cde101f0116 - -519.4864 - 0.0 - 1.5 - 12.985 - - HöS_HS_MS + - HoeS_HS_MS - 0.1444 - 0.5776 - 1.1552