Skip to content

Commit bbbcf01

Browse files
authored
Merge pull request #6 from dwrobel/dw-fix-Celsius-character
Fix Celsius character
2 parents c23dca4 + 1ebde82 commit bbbcf01

File tree

1 file changed

+19
-19
lines changed

1 file changed

+19
-19
lines changed

src/OpenTherm.h

Lines changed: 19 additions & 19 deletions
Original file line numberDiff line numberDiff line change
@@ -29,45 +29,45 @@ enum OpenThermRequestType {
2929

3030
enum OpenThermMessageID {
3131
Status, // flag8 / flag8 Master and Slave Status flags.
32-
TSet, // f8.8 Control setpoint ie CH water temperature setpoint (°C)
32+
TSet, // f8.8 Control setpoint ie CH water temperature setpoint (°C)
3333
MConfigMMemberIDcode, // flag8 / u8 Master Configuration Flags / Master MemberID Code
3434
SConfigSMemberIDcode, // flag8 / u8 Slave Configuration Flags / Slave MemberID Code
3535
Command, // u8 / u8 Remote Command
3636
ASFflags, // / OEM-fault-code flag8 / u8 Application-specific fault flags and OEM fault code
3737
RBPflags, // flag8 / flag8 Remote boiler parameter transfer-enable & read/write flags
3838
CoolingControl, // f8.8 Cooling control signal (%)
39-
TsetCH2, // f8.8 Control setpoint for 2e CH circuit (°C)
39+
TsetCH2, // f8.8 Control setpoint for 2e CH circuit (°C)
4040
TrOverride, // f8.8 Remote override room setpoint
4141
TSP, // u8 / u8 Number of Transparent-Slave-Parameters supported by slave
4242
TSPindexTSPvalue, // u8 / u8 Index number / Value of referred-to transparent slave parameter.
4343
FHBsize, // u8 / u8 Size of Fault-History-Buffer supported by slave
4444
FHBindexFHBvalue, // u8 / u8 Index number / Value of referred-to fault-history buffer entry.
4545
MaxRelModLevelSetting, // f8.8 Maximum relative modulation level setting (%)
4646
MaxCapacityMinModLevel, // u8 / u8 Maximum boiler capacity (kW) / Minimum boiler modulation level(%)
47-
TrSet, // f8.8 Room Setpoint (°C)
47+
TrSet, // f8.8 Room Setpoint (°C)
4848
RelModLevel, // f8.8 Relative Modulation Level (%)
4949
CHPressure, // f8.8 Water pressure in CH circuit (bar)
5050
DHWFlowRate, // f8.8 Water flow rate in DHW circuit. (litres/minute)
5151
DayTime, // special / u8 Day of Week and Time of Day
5252
Date, // u8 / u8 Calendar date
5353
Year, // u16 Calendar year
54-
TrSetCH2, // f8.8 Room Setpoint for 2nd CH circuit (°C)
55-
Tr, // f8.8 Room temperature (°C)
56-
Tboiler, // f8.8 Boiler flow water temperature (°C)
57-
Tdhw, // f8.8 DHW temperature (°C)
58-
Toutside, // f8.8 Outside temperature (°C)
59-
Tret, // f8.8 Return water temperature (°C)
60-
Tstorage, // f8.8 Solar storage temperature (°C)
61-
Tcollector, // f8.8 Solar collector temperature (°C)
62-
TflowCH2, // f8.8 Flow water temperature CH2 circuit (°C)
63-
Tdhw2, // f8.8 Domestic hot water temperature 2 (°C)
64-
Texhaust, // s16 Boiler exhaust temperature (°C)
65-
TdhwSetUBTdhwSetLB = 48, // s8 / s8 DHW setpoint upper & lower bounds for adjustment (°C)
66-
MaxTSetUBMaxTSetLB, // s8 / s8 Max CH water setpoint upper & lower bounds for adjustment (°C)
54+
TrSetCH2, // f8.8 Room Setpoint for 2nd CH circuit (°C)
55+
Tr, // f8.8 Room temperature (°C)
56+
Tboiler, // f8.8 Boiler flow water temperature (°C)
57+
Tdhw, // f8.8 DHW temperature (°C)
58+
Toutside, // f8.8 Outside temperature (°C)
59+
Tret, // f8.8 Return water temperature (°C)
60+
Tstorage, // f8.8 Solar storage temperature (°C)
61+
Tcollector, // f8.8 Solar collector temperature (°C)
62+
TflowCH2, // f8.8 Flow water temperature CH2 circuit (°C)
63+
Tdhw2, // f8.8 Domestic hot water temperature 2 (°C)
64+
Texhaust, // s16 Boiler exhaust temperature (°C)
65+
TdhwSetUBTdhwSetLB = 48, // s8 / s8 DHW setpoint upper & lower bounds for adjustment (°C)
66+
MaxTSetUBMaxTSetLB, // s8 / s8 Max CH water setpoint upper & lower bounds for adjustment (°C)
6767
HcratioUBHcratioLB, // s8 / s8 OTC heat curve ratio upper & lower bounds for adjustment
68-
TdhwSet = 56, // f8.8 DHW setpoint (°C) (Remote parameter 1)
69-
MaxTSet, // f8.8 Max CH water setpoint (°C) (Remote parameters 2)
70-
Hcratio, // f8.8 OTC heat curve ratio (°C) (Remote parameter 3)
68+
TdhwSet = 56, // f8.8 DHW setpoint (°C) (Remote parameter 1)
69+
MaxTSet, // f8.8 Max CH water setpoint (°C) (Remote parameters 2)
70+
Hcratio, // f8.8 OTC heat curve ratio (°C) (Remote parameter 3)
7171
RemoteOverrideFunction = 100, // flag8 / - Function of manual and program changes in master and remote room setpoint.
7272
OEMDiagnosticCode = 115, // u16 OEM-specific diagnostic/service code
7373
BurnerStarts, // u16 Number of starts burner

0 commit comments

Comments
 (0)