Skip to content

Vaillant VRC 700/4f: legionella is missing #516

@pulla2908

Description

@pulla2908

My setup is up and running since a few days. In Home Assistant via MQTT I have a lot of entities created except those for legionella. mqtt-hassio.cfg and configuration-files are local stored (fetched from the git repositories).

I checked the log file and I realized there is no legionella information in the csv files which gets loaded in my case. Here is the output from the log from the scan:

2025-08-01 16:34:09.151 [main notice] starting initial broadcast scan
2025-08-01 16:34:09.240 [update notice] sent write broadcast queryexistence QQ=31: 
2025-08-01 16:34:09.726 [update notice] received unknown MS cmd: 1008b5110101 / 094f440080ffff0000ff
2025-08-01 16:34:09.989 [update notice] received unknown MS cmd: 1076b5110101 / 0945440080ff630000ff
2025-08-01 16:34:10.265 [update notice] received unknown MS cmd: 1076b512030f0001 / 071803002e0212ff
2025-08-01 16:34:10.782 [update notice] received unknown MS cmd: 1076b51009000000ffffff010000 / 0101
2025-08-01 16:34:11.094 [update notice] received unknown MS cmd: 7108b5110107 / 0a00500080003600000000
2025-08-01 16:34:13.947 [update notice] received unknown MS cmd: 7108b5110107 / 0a00500080003600000000
2025-08-01 16:34:15.726 [update notice] received unknown MS cmd: 7108b5120e117b022102090233021200000600 / 020000
2025-08-01 16:34:17.226 [update notice] received unknown MS cmd: f115b52406020003001b00 / 0601031b000000
2025-08-01 16:34:17.406 [update notice] received unknown MS cmd: 7108b5110107 / 0a00500080003600000000
2025-08-01 16:34:17.506 [update notice] received unknown MS cmd: f115b52406020001000f00 / 0601010f000000
2025-08-01 16:34:19.401 [update notice] store 08 ident: done
2025-08-01 16:34:19.401 [update notice] sent scan-read scan.08  QQ=31: Vaillant;HMU00;0522;5103
2025-08-01 16:34:19.408 [main notice] read common config file vaillant/scan.csv
2025-08-01 16:34:19.408 [main notice] read common config file vaillant/general.csv
2025-08-01 16:34:19.409 [main notice] read common config file vaillant/broadcast.csv
2025-08-01 16:34:19.411 [main notice] read scan config file vaillant/08.hmu.csv for ID "hmu00", SW0522, HW5103
2025-08-01 16:34:19.412 [main notice] found messages: 66 (0 conditional on 0 conditions, 0 poll, 10 update)
2025-08-01 16:34:19.600 [update notice] sent unknown MS cmd: 3108b5090124 / 09003231323232313030
2025-08-01 16:34:19.764 [update notice] sent scan-read scan.08 id QQ=31: 
2025-08-01 16:34:19.860 [update notice] received read hmu Status01 QQ=10: 39.5;34.0;-;-;-;off
2025-08-01 16:34:19.969 [update notice] sent scan-read scan.08 id QQ=31: 
2025-08-01 16:34:20.110 [update notice] sent scan-read scan.08 id QQ=31: 21;22;21;0010021619;0001;006253;N0
2025-08-01 16:34:20.243 [update notice] received unknown MS cmd: 1076b5110101 / 0945440080ff630000ff
2025-08-01 16:34:20.507 [update notice] received unknown MS cmd: 1076b512030f0001 / 071803002e0212ff
2025-08-01 16:34:20.720 [update notice] received unknown BC cmd: 10feb505025c00
2025-08-01 16:34:20.857 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:34:21.033 [update notice] received update-write hmu SetMode QQ=10: auto;0.0;-;-;1;1;1;0;0;0
2025-08-01 16:34:21.297 [update notice] received unknown MS cmd: 1076b51009000000ffffff010000 / 0101
2025-08-01 16:34:21.535 [update notice] received update-read broadcast vdatetime QQ=10: 16:34:19;01.08.2025
2025-08-01 16:34:21.774 [update notice] received unknown MS cmd: 1008b507020900 / 022d06
2025-08-01 16:34:22.039 [update notice] received unknown MS cmd: 1008b5110100 / 097b0212000000000000
2025-08-01 16:34:22.303 [update notice] store 15 ident: done
2025-08-01 16:34:22.303 [update notice] sent scan-read scan.15  QQ=31: Vaillant;B7V00;0422;5503
2025-08-01 16:34:22.372 [update notice] received unknown MS cmd: 1076b51303040d00 / 020d00
2025-08-01 16:34:22.503 [update notice] sent unknown MS cmd: 3115b5090124 / 09003231323133393030
2025-08-01 16:34:22.659 [update notice] sent scan-read scan.15 id QQ=31: 
2025-08-01 16:34:22.747 [update notice] received update-read broadcast outsidetemp QQ=10: 25.328
2025-08-01 16:34:22.864 [update notice] sent scan-read scan.15 id QQ=31: 
2025-08-01 16:34:23.014 [update notice] sent scan-read scan.15 id QQ=31: 21;21;39;0020197207;0082;018791;N6
2025-08-01 16:34:23.033 [main notice] read scan config file vaillant/15.b7v.csv for ID "b7v00", SW0422, HW5503
2025-08-01 16:34:23.033 [main notice] found messages: 534 (0 conditional on 0 conditions, 0 poll, 10 update)
2025-08-01 16:34:23.743 [update notice] received unknown MS cmd: 7108b5120e117a022102090233021200000600 / 020000
2025-08-01 16:34:24.318 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:34:25.205 [update notice] store 76 ident: done
2025-08-01 16:34:25.205 [update notice] sent scan-read scan.76  QQ=31: Vaillant;VWZ00;0522;5103
2025-08-01 16:34:25.303 [update notice] received read b7v currenterror QQ=f1: -;-;-;-;-
2025-08-01 16:34:25.405 [update notice] sent unknown MS cmd: 3176b5090124 / 09003231323232303030
2025-08-01 16:34:25.562 [update notice] sent scan-read scan.76 id QQ=31: 
2025-08-01 16:34:25.660 [update notice] received unknown MS cmd: f115b503020002 / 0affffffffffffffffffff
2025-08-01 16:34:25.772 [update notice] sent scan-read scan.76 id QQ=31: 
2025-08-01 16:34:25.914 [update notice] sent scan-read scan.76 id QQ=31: 21;22;20;0010023504;1610;005394;N2
2025-08-01 16:34:25.915 [main error] unable to load scan config 76: no file from vaillant with prefix 76 found
2025-08-01 16:34:25.915 [main error] scan config 76: ERR: element not found
2025-08-01 16:34:26.013 [update notice] received read hmu currenterror QQ=f1: -;-;-;-;-
2025-08-01 16:34:26.197 [update notice] received unknown MS cmd: f108b503020002 / 0affffffffffffffffffff
2025-08-01 16:34:26.381 [update notice] received unknown MS cmd: f108b503020004 / 0affffffffffffffffffff
2025-08-01 16:34:26.525 [update notice] received unknown MS cmd: f108b503020005 / 00
2025-08-01 16:34:26.708 [update notice] received unknown MS cmd: f176b503020001 / 0affffffffffffffffffff
2025-08-01 16:34:27.765 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:34:28.108 [update notice] store f6 ident: done
2025-08-01 16:34:28.108 [update notice] sent scan-read scan.f6  QQ=31: Vaillant;NETX3;0126;0404
2025-08-01 16:34:28.280 [update notice] sent unknown MS cmd: 31f6b5090124 / 09003231323431353030
2025-08-01 16:34:28.437 [update notice] sent scan-read scan.f6 id QQ=31: 
2025-08-01 16:34:28.608 [update notice] sent scan-read scan.f6 id QQ=31: 
2025-08-01 16:34:28.780 [update notice] sent scan-read scan.f6 id QQ=31: 21;24;15;0020292012;0933;043857;N5
2025-08-01 16:34:28.781 [main error] unable to load scan config f6: no file from vaillant with prefix f6 found
2025-08-01 16:34:28.781 [main error] scan config f6: ERR: element not found
2025-08-01 16:34:29.793 [update notice] received read hmu Status01 QQ=10: 39.5;34.0;-;-;-;off
2025-08-01 16:34:30.054 [update notice] received unknown MS cmd: 1076b5110101 / 0945440080ff630000ff
2025-08-01 16:34:30.318 [update notice] received unknown MS cmd: 1076b512030f0001 / 071803002d0212ff
2025-08-01 16:34:30.582 [update notice] received update-write hmu SetMode QQ=10: auto;0.0;-;-;1;1;1;0;0;0
2025-08-01 16:34:30.846 [update notice] received unknown MS cmd: 1076b51009000000ffffff010000 / 0101
2025-08-01 16:34:31.202 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:34:31.754 [update notice] received unknown MS cmd: 7108b5120e117b022002080233021200000600 / 020000
2025-08-01 16:34:31.981 [update notice] sent poll-read b7v AdaptHeatCurve QQ=31: no
2025-08-01 16:34:33.219 [update notice] received unknown MS cmd: f115b52406020003001b00 / 0601031b000000
2025-08-01 16:34:33.404 [update notice] received unknown MS cmd: f115b52406020001000f00 / 0601010f000000
2025-08-01 16:34:34.635 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:34:38.103 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:34:39.750 [update notice] received unknown MS cmd: 7108b5120e117b022002080233021200000600 / 020000
2025-08-01 16:34:39.840 [update notice] received read hmu Status01 QQ=10: 39.5;34.0;-;-;-;off
2025-08-01 16:34:40.104 [update notice] received unknown MS cmd: 1076b5110101 / 0945440080ff630000ff
2025-08-01 16:34:40.367 [update notice] received unknown MS cmd: 1076b512030f0001 / 071803002d0212ff
2025-08-01 16:34:40.632 [update notice] received update-write hmu SetMode QQ=10: auto;0.0;-;-;1;1;1;0;0;0
2025-08-01 16:34:40.895 [update notice] received unknown MS cmd: 1076b51009000000ffffff010000 / 0101
2025-08-01 16:34:41.254 [update notice] received unknown MS cmd: f115b52406020000004800 / 06010048000000
2025-08-01 16:34:41.440 [update notice] received poll-read b7v Hc1PumpStatus QQ=f1: 0
2025-08-01 16:34:41.532 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:34:41.680 [update notice] received poll-read b7v Hc1ActualFlowTempDesired QQ=f1: 0.0
2025-08-01 16:34:41.865 [update notice] received poll-read b7v Hc2PumpStatus QQ=f1: 0
2025-08-01 16:34:42.058 [update notice] received poll-read b7v Hc2ActualFlowTempDesired QQ=f1: 0.0
2025-08-01 16:34:42.243 [update notice] received poll-read b7v Hc3PumpStatus QQ=f1: 0
2025-08-01 16:34:42.435 [update notice] received poll-read b7v Hc3ActualFlowTempDesired QQ=f1: 0.0
2025-08-01 16:34:42.620 [update notice] received unknown MS cmd: f115b52406020002031e00 / 0600021e000000
2025-08-01 16:34:42.813 [update notice] received unknown MS cmd: f115b52406020002030700 / 080002070000000000
2025-08-01 16:34:43.006 [update notice] received poll-read b7v z1DayTemp QQ=f1: 22.5
2025-08-01 16:34:43.200 [update notice] received poll-read b7v z1ActualRoomTempDesired QQ=f1: 0.0
2025-08-01 16:34:43.385 [update notice] received poll-read b7v z1OpMode QQ=f1: off
2025-08-01 16:34:43.578 [update notice] received unknown MS cmd: f115b52406020003001500 / 08030315000000ac41
2025-08-01 16:34:44.986 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:34:47.186 [update notice] sent poll-read b7v ccTimer.Friday QQ=31: 06:00;22:00;-:-;-:-;-:-;-:-
2025-08-01 16:34:47.739 [update notice] received unknown MS cmd: 7108b5120e117b022002080233021200000600 / 020000
2025-08-01 16:34:48.402 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:34:49.249 [update notice] received unknown MS cmd: f115b52406020003001b00 / 0601031b000000
2025-08-01 16:34:49.428 [update notice] received unknown MS cmd: f115b52406020001000f00 / 0601010f000000
2025-08-01 16:34:49.824 [update notice] received read hmu Status01 QQ=10: 39.5;34.0;-;-;-;off
2025-08-01 16:34:50.028 [update notice] received unknown MS cmd: 7108b51a03042532 / 0e2507c0cfc07b3c00b01b20000000
2025-08-01 16:34:50.162 [update notice] received unknown MS cmd: 1076b5110101 / 0945440080ff630000ff
2025-08-01 16:34:50.410 [update notice] received unknown MS cmd: 7108b51a03042633 / 0e260000008a000000000000000000
2025-08-01 16:34:50.499 [update notice] received unknown MS cmd: 1076b512030f0001 / 071803002d0212ff
2025-08-01 16:34:50.763 [update notice] received update-write hmu SetMode QQ=10: auto;0.0;-;-;1;1;1;0;0;0
2025-08-01 16:34:50.968 [update notice] received unknown MS cmd: 7108b51a03042734 / 0e27cf2000c0022101001800061800
2025-08-01 16:34:51.101 [update notice] received unknown MS cmd: 1076b51009000000ffffff010000 / 0101
2025-08-01 16:34:51.306 [update notice] received unknown MS cmd: 7108b51a03042835 / 0e2800000000000100b00100000000
2025-08-01 16:34:51.686 [update notice] received unknown MS cmd: 7108b51a03042936 / 0e2900000000000000000000000000
2025-08-01 16:34:52.173 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:34:55.598 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:34:55.886 [update notice] received unknown MS cmd: 7108b5120e117b022002080233021200000600 / 020000
2025-08-01 16:34:59.048 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:34:59.837 [update notice] received read hmu Status01 QQ=10: 39.5;34.0;-;-;-;off
2025-08-01 16:35:00.105 [update notice] received unknown MS cmd: 1076b5110101 / 0945440080ff630000ff
2025-08-01 16:35:00.365 [update notice] received unknown MS cmd: 1076b512030f0001 / 071803002d0212ff
2025-08-01 16:35:00.630 [update notice] received update-write hmu SetMode QQ=10: auto;0.0;-;-;1;1;1;0;0;0
2025-08-01 16:35:00.893 [update notice] received unknown MS cmd: 1076b51009000000ffffff010000 / 0101
2025-08-01 16:35:02.520 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:35:03.162 [update notice] sent poll-read b7v ccTimer.Monday QQ=31: 06:00;22:00;-:-;-:-;-:-;-:-
2025-08-01 16:35:03.759 [update notice] received unknown MS cmd: 7108b5120e117a022002080233021200000600 / 020000
2025-08-01 16:35:04.255 [update notice] received unknown MS cmd: f108b509055402005b0d / 0802015b0d0000d040
2025-08-01 16:35:04.431 [update notice] received read hmu Status01 QQ=f1: 39.5;34.0;-;-;-;off
2025-08-01 16:35:05.231 [update notice] received unknown MS cmd: f115b52406020003001b00 / 0601031b000000
2025-08-01 16:35:05.415 [update notice] received unknown MS cmd: f115b52406020001000f00 / 0601010f000000
2025-08-01 16:35:05.945 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:35:09.414 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:35:09.896 [update notice] received read hmu Status01 QQ=10: 39.5;34.0;-;-;-;off
2025-08-01 16:35:10.159 [update notice] received unknown MS cmd: 1076b5110101 / 0945440080ff630000ff
2025-08-01 16:35:10.423 [update notice] received unknown MS cmd: 1076b512030f0001 / 071803002d0212ff
2025-08-01 16:35:10.688 [update notice] received update-write hmu SetMode QQ=10: auto;0.0;-;-;1;1;1;0;0;0
2025-08-01 16:35:10.952 [update notice] received unknown MS cmd: 1076b51009000000ffffff010000 / 0101
2025-08-01 16:35:11.766 [update notice] received unknown MS cmd: 7108b5120e117a022002080233021200000600 / 020000
2025-08-01 16:35:12.824 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:35:16.292 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:35:17.221 [update notice] received unknown MS cmd: f108b503020003 / 0a6400ffffffffffffffff
2025-08-01 16:35:17.414 [update notice] received poll-read b7v DisplayedOutsideTemp QQ=f1: 25.3281
2025-08-01 16:35:17.608 [update notice] received poll-read b7v z1RoomTemp QQ=f1: 23.5625
2025-08-01 16:35:17.792 [update notice] received poll-read b7v z1OpModeCooling QQ=f1: auto
2025-08-01 16:35:17.985 [update notice] received poll-read b7v z1CoolingTemp QQ=f1: 21.5
2025-08-01 16:35:18.178 [update notice] received poll-read b7v Hc1FlowTemp QQ=f1: 39.5
2025-08-01 16:35:18.371 [update notice] received poll-read b7v Hc2FlowTemp QQ=f1: 
2025-08-01 16:35:18.565 [update notice] received poll-read b7v Hc3FlowTemp QQ=f1: 
2025-08-01 16:35:18.759 [update notice] received unknown MS cmd: f115b52406020002030800 / 080002080000004642
2025-08-01 16:35:18.952 [update notice] received poll-read b7v HwcTempDesired QQ=f1: 50
2025-08-01 16:35:19.137 [update notice] received poll-read b7v HwcOpMode QQ=f1: auto
2025-08-01 16:35:19.260 [update notice] sent poll-read b7v ccTimer.Saturday QQ=31: 07:30;23:30;-:-;-:-;-:-;-:-
2025-08-01 16:35:19.410 [update notice] received poll-read b7v HwcStorageTemp QQ=f1: 49.5
2025-08-01 16:35:19.605 [update notice] received poll-read b7v SystemFlowTemp QQ=f1: 
2025-08-01 16:35:19.740 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:35:19.846 [update notice] received read b7v WaterPressure QQ=f1: 1.8
2025-08-01 16:35:19.936 [update notice] received read hmu Status01 QQ=10: 39.5;34.0;-;-;-;off
2025-08-01 16:35:20.073 [update notice] received read b7v HwcParallelLoading QQ=f1: off
2025-08-01 16:35:20.184 [update notice] received unknown MS cmd: 7108b5120e117a022002080232021200000600 / 020000
2025-08-01 16:35:20.316 [update notice] received unknown MS cmd: 1076b5110101 / 0945440080ff630000ff
2025-08-01 16:35:20.466 [update notice] received poll-read b7v HcStorageTempBottom QQ=f1: 
2025-08-01 16:35:20.642 [update notice] received unknown MS cmd: 1076b512030f0001 / 071803002d0212ff
2025-08-01 16:35:20.792 [update notice] received poll-read b7v HwcStorageTempBottom QQ=f1: 
2025-08-01 16:35:20.918 [update notice] received unknown BC cmd: 10feb505025c00
2025-08-01 16:35:21.067 [update notice] received poll-read b7v HcStorageTempTop QQ=f1: 
2025-08-01 16:35:21.244 [update notice] received update-write hmu SetMode QQ=10: auto;0.0;-;-;1;1;1;0;0;0
2025-08-01 16:35:21.393 [update notice] received poll-read b7v HwcStorageTempTop QQ=f1: 
2025-08-01 16:35:21.570 [update notice] received unknown MS cmd: 1076b51009000000ffffff010000 / 0101
2025-08-01 16:35:21.719 [update notice] received unknown MS cmd: f115b5240602000000a200 / 080300a20000002041
2025-08-01 16:35:21.871 [update notice] received update-read broadcast vdatetime QQ=10: 16:35:19;01.08.2025
2025-08-01 16:35:21.985 [update notice] received unknown MS cmd: f115b5240602000000b600 / 00
2025-08-01 16:35:22.136 [update notice] received unknown MS cmd: 1008b507020900 / 022d06
2025-08-01 16:35:22.274 [update notice] received read b7v GlobalSystemOff QQ=f1: no
2025-08-01 16:35:22.449 [update notice] received unknown MS cmd: 1008b5110100 / 097a0212000000000000
2025-08-01 16:35:22.599 [update notice] received unknown MS cmd: f115b52406060009010700 / 080109070000007c42
2025-08-01 16:35:22.754 [update notice] received unknown MS cmd: 1076b51303040d00 / 020d00
2025-08-01 16:35:22.894 [update notice] received unknown MS cmd: f115b52406020003001b00 / 0601031b000000
2025-08-01 16:35:23.024 [update notice] received update-read broadcast outsidetemp QQ=10: 25.328
2025-08-01 16:35:23.160 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:35:23.257 [update notice] received unknown MS cmd: f115b52406020001000f00 / 0601010f000000
2025-08-01 16:35:23.356 [update notice] received update-write hmu StatusCirPump QQ=10: on
2025-08-01 16:35:23.586 [update notice] received unknown MS cmd: 1008b5120204ff / 00
2025-08-01 16:35:23.820 [update notice] received unknown MS cmd: 1008b513020528 / 0101
2025-08-01 16:35:24.033 [update notice] received unknown BC cmd: 10feb510020601
2025-08-01 16:35:25.270 [update notice] received read b7v currenterror QQ=f1: -;-;-;-;-
2025-08-01 16:35:25.454 [update notice] received unknown MS cmd: f115b503020002 / 0affffffffffffffffffff
2025-08-01 16:35:25.638 [update notice] received read hmu currenterror QQ=f1: -;-;-;-;-
2025-08-01 16:35:25.822 [update notice] received unknown MS cmd: f108b503020002 / 0affffffffffffffffffff
2025-08-01 16:35:26.011 [update notice] received unknown MS cmd: f108b503020004 / 0affffffffffffffffffff
2025-08-01 16:35:26.150 [update notice] received unknown MS cmd: f108b503020005 / 00
2025-08-01 16:35:26.333 [update notice] received unknown MS cmd: f176b503020001 / 0affffffffffffffffffff
2025-08-01 16:35:26.647 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:35:27.767 [update notice] received unknown MS cmd: 7108b5120e117a022002080232021200000600 / 020000
2025-08-01 16:35:29.915 [update notice] received read hmu Status01 QQ=10: 39.5;34.0;-;-;-;off
2025-08-01 16:35:30.052 [update notice] received read hmu State QQ=71: 0;80;128;0
2025-08-01 16:35:30.228 [update notice] received unknown MS cmd: 1076b5110101 / 0945440080ff630000ff
2025-08-01 16:35:30.492 [update notice] received unknown MS cmd: 1076b512030f0001 / 071803002d0212ff
2025-08-01 16:35:30.757 [update notice] received update-write hmu SetMode QQ=10: auto;0.0;-;-;1;1;1;0;0;0
2025-08-01 16:35:30.784 [main notice] scan completed 1 time(s), check again

Here the info output via telnet session:

version:ebusd25.1.p20250414
device:192.168.8.154:9999,TCP,enhanced,firmware1.1[560f].1[560f]
access:*
signal:acquired
symbolrate:55
maxsymbolrate:170
minarbitrationmicros:1
maxarbitrationmicros:8
minsymbollatency:4
maxsymbollatency:26
scan:finished
reconnects:0
masters:5
messages:706
conditional:0
poll:253
update:29
address03:master#11
address08:slave#11,scanned"MF=Vaillant;ID=HMU00;SW=0522;HW=5103",loaded"vaillant/08.hmu.csv"
address10:master#2
address15:slave#2,scanned"MF=Vaillant;ID=B7V00;SW=0422;HW=5503",loaded"vaillant/15.b7v.csv"
address31:master#8,ebusd
address36:slave#8,ebusd
address71:master#9
address76:slave#9,scanned"MF=Vaillant;ID=VWZ00;SW=0522;HW=5103",loaded"vaillant/76.vwz.csv"
addressf1:master#10
addressf6:slave#10,scanned"MF=Vaillant;ID=NETX3;SW=0126;HW=0404"

My questions is: What is the approach here for me to get legionella as well? Modify e.g. 15.b7v.csv and add these settings by my own?