Subscriber view

Change between views using the change view button in the lower right grafik. Change between GOOSE and SV using the grafik or grafik buttons. The subscriber view looks similar to that shown below:

grafik

To subscribe:

  • Click on an External Reference in the left column
  • Click on a published FCDA in the right column
  • When a subscription is done a supervision is automatically allocated unless this option is disabled (see Settings) A small heart-beat icon image:supervision.png[width=25] is shown and details of the supervision are shown (also shown when hovering over the icon).
  • To the right of each FCDA a number shows the total subscriptions to that FCDA within the file

To unsubscribe click on an External Reference in the left column

TIP: If you find it too easy to unsubscribe while viewing mappings, use the <<ReadOnlyView,read-only view>> setting.

Invalid or Missing Subscriptions

include::partial$invalid_or_missing.adoc[]

== Export to Markdown:

When clicking on the "Export to Markdown" button image:export_to_markdown.png[width=25px], the results of the current filter are copied to the clipboard. This can be pasted into documents or spreadsheets and may be useful for recording test results.

An illustrative output is shown below:

Markdown Output

  • 📦 XAT_2242_MU1 MERGING UNIT - TP version: 2.0.0 - NRR - PCS-221S

    • 🔗 MUGO / LLN0: 1-A:MUGO/GOINGGIO1.SPCSO1.stVal ⬅ XAT_T1_P1 > ANN / PSV GGIO 1 Ind60.stVal Bay Trip - 3 Pole ⬅ Annunciation > MV/LV CB Trip (CFG / LLN0 Ctl, 💓 LD0 > LGOS 1)

    • 🔗 MUGO / LLN0: 1-A:MUGO/GOINGGIO1.SPCSO1.q ⬅ XAT_T1_P1 > ANN / PSV GGIO 1 Ind60.q Bay Trip - 3 Pole (q) ⬅ Annunciation > MV/LV CB Trip (CFG / LLN0 Ctl, 💓 LD0 > LGOS 1)

    • 🔗 MUGO / LLN0: 1-A:MUGO/GOINGGIO1.SPCSO6.stVal ⬅ XAT_T1_P1 > ANN / PSV GGIO 1 Ind59.stVal Bay Manual Close - 3 Pole ⬅ Annunciation > MV/LV CB Close (CFG / LLN0 Ctl, 💓 LD0 > LGOS 1)

    • 🔗 MUGO / LLN0: 1-A:MUGO/GOINGGIO1.SPCSO6.q ⬅ XAT_T1_P1 > ANN / PSV GGIO 1 Ind59.q Bay Manual Close - 3 Pole (q) ⬅ Annunciation > MV/LV CB Close (CFG / LLN0 Ctl, 💓 LD0 > LGOS 1)


Filtering

Published data can be filtered by one or more of:

  • Subscribed
  • Not Subscribed
  • Data Objects
  • Quality

It can be convenient to filter by "Not Subscribed" while carrying out mappings, as items will be removed from the list once they are subscribed.

If using add-on plugins to provide manufacturer-specific functionality, it can be convenient to filter out quality where it will automatically be mapped for the user.

TIP: It is recommended only to filter out quality and rely on an additional plugin as part of an engineering process where it is known that quality will be mapped correctly.

Subscribed data can be filtered by:

  • Subscribed
  • Not Subscribed
  • Unspecified service types. Both GOOSE and SV traffic when configured have a serviceType or pServT attribute which specified GOOSE or SV traffic. It is an optional field and can be missing. For some devices it may be useful to ignore traffic without a service type.
  • Preconfigured Quality Attribute. Hides or shows ExtRef elements attributes which are defined as quality attributes (according to IEC 61850 Ed 2.1).
  • Preconfigured Time Attribute. Hides or shows ExtRef elements attributes which are defined as time attributes (according to IEC 61850 Ed 2.1).

Sorting

Within the publishing view, published data can be sorted by:

  • Data Model - the order of the file
  • Object Reference - the full path of the object within the SCL file
  • Full Description - the concatenated descriptions (based on the desc attribute) of Logical Device, Logical Node, Data Object and Data Attribute description
  • Data Object and Data Attribute
  • Data Attribute

Subscribed data can be sorted by:

  • Data model - the order of the file

  • Internal address - the intAddr of each External Reference

  • Description - the desc attribute of each External Reference

  • Mapped Reference. Sort according to the reference of the published data. If the published data (in the right hand column) is also sorted by "Object reference", the two columns may be directly compared.

Settings

The following setting options can be selected by clicking on the settings button grafik.

  • Auto-increment. Move to the next External Reference when a mapping is complete. On by default.
  • Change Supervision LNs. This option is on by default. If turned off, supervisions will not be allocated as subscriptions are mapped.

NOTE: For some manufacturers (notably, GE) this may result in subscriptions not being fully configured/functional

  • Allow External Plugins - This option is on by default.
  • Check Only Preconfigured Service and Basic Types. This option is off by default. When on, the CDC (common data class) checks for IEC 61850-6 Ed 2.1 are not carried out and mapping is allowed between incompatible CDCs. This would be required, for instance when mapping a trip signal (LN PTRC and CDC ACT on the published data) to an input (with CDC SPS in preconfigured attributes on an External Reference).
  • Read-only view. In this view, the user may click on published or subscribed data without risk of creating or removing a mapping. The highlight color changes and a small padlock grafik is shown near the top of the left hand column.

Datatype information

By hovering over a published item, the common data class and the basic type are displayed.

TIP: These can only be shown for external references unless preferred attributes are configured.